Industrial IoT Pilot for One Production Line or Machine Group
The Industrial IoT Pilot is for manufacturers ready to prove value on one production line or defined machine group: we deliver gateway and data acquisition, a dashboard, alerts, an acceptance test and a rollout recommendation. You see real machine data and measurable results before committing to a plant wide deployment.
Pricing: On Request
Who this is for
- Plant head or operations director
- Manufacturing engineering manager
- Maintenance manager
- IT or OT manager
- Digital transformation lead
Outcomes we work towards
- Live, trusted machine data from one line
- Measured results against an agreed baseline
- Validated architecture before plant wide rollout
- A rollout plan based on pilot evidence
Plant wide rollouts without proof carry high risk
Committing to plant wide Industrial IoT before proving data quality, user adoption and measurable value is a large gamble. Vendor demos run on clean data, not on a twenty year old press with an undocumented controller. Without a pilot, teams discover integration issues, unreliable signals and dashboards nobody uses after the full budget is spent. A tightly scoped pilot on one line answers those questions with real data and limits the investment until value is shown.
What We Design, Build and Hand Over
- Pilot definition confirming line or machine group, data points, KPIs and acceptance criteria
- Industrial gateway configuration for PLC, machine and sensor data acquisition
- Retrofit sensor integration where machines expose no usable controller data, when agreed in the SOW
- Secure data path from gateway to on premises or cloud platform
- Dashboard for agreed views such as OEE, downtime, cycle count or machine state
- Alert rules for stoppages, thresholds or condition changes, routed to agreed recipients
- Acceptance test verifying data accuracy against machine counters and operator records
- Operator and maintenance team walkthrough of dashboards and alerts
- Rollout recommendation with architecture, effort and lessons from the pilot
Pilot architecture from machine to dashboard
The pilot builds a complete but limited data path for one line, using the same layers a plant wide rollout would use, so architecture, security and data quality are validated at small scale.
Step 1
Machines and PLCs
Existing controllers and machines on the pilot line, with control logic left unchanged
Step 2
Sensors and retrofit
Added current, vibration or count sensors where controller data is missing
Step 3
Industrial gateway
Protocol acquisition, local buffering and store and forward during network outages
Step 4
Secure transport
Encrypted MQTT or OPC UA link across a segmented OT network
Step 5
Data platform
Time series storage and event processing on premises or in the cloud
Step 6
Dashboards and alerts
Line level views and notifications for operators, maintenance and managers
Where Teams Use This
OEE visibility on a bottleneck line
A plant suspects its bottleneck line loses capacity to short stops. The pilot captures machine states and counts to show availability, performance and quality losses that manual logs miss.
Downtime alerts for critical machines
Maintenance learns about stoppages late. The pilot sends alerts on machine stops and threshold breaches, so the team can measure response times and recurring causes on a defined machine group.
Condition monitoring trial
A maintenance team wants to test vibration or current monitoring on motors and spindles before wider investment. The pilot collects condition data and validates whether signals are useful.
Energy visibility per line
Energy costs are known per site, not per line. The pilot meters a line and correlates consumption with production, giving a measured view of energy per part.
How the Work Runs
Pilot definition
We confirm line, machines, data points, KPIs, baseline and acceptance criteria, ideally from a completed readiness assessment, and agree the SOW.
Design and preparation
Engineers finalise architecture, gateway configuration, network and security design, and coordinate installation requirements with your team.
Connection and data acquisition
We configure gateways and integrate PLCs, machines and sensors, then verify signals against machine counters and operator observations.
Dashboards and alerts
We build the agreed dashboard views and alert rules, and review them with operators and maintenance for usefulness and clarity.
Acceptance and measurement
The acceptance test confirms data accuracy and function, then results are measured against the baseline over the agreed window.
Rollout recommendation
We report pilot results, lessons and a recommended architecture, phasing and effort estimate for wider deployment.
What You Receive
- Pilot scope and acceptance criteria document
- Configured gateway and data acquisition for the pilot line
- Dashboard with agreed views
- Alert rules and notification routing
- Acceptance test report
- Pilot results against baseline
- Architecture and configuration documentation
- Rollout recommendation with effort estimate
Related Case Studies
Smart Manufacturing IoT Platform for an Auto Parts Maker
STM32H7 edge nodes with TinyML connect legacy CNC machines over OPC UA and Modbus RTU to AWS IoT Greengrass dashboards for an auto parts maker.
Industrial Predictive Maintenance System with Edge AI
Jetson Orin Nano edge modules analyze vibration and current signatures on CNC machines and motors, with Modbus TCP shutdowns and Azure IoT Hub analytics.
Have a similar challenge?
Share a short brief; an engineer replies within one business day. How engagements work
Related Pages
- Factory IoT Implementation for Plant and Automation Teams
- Industrial IoT Gateway
- OEE Monitoring
- Machine Monitoring
- Factory IoT Readiness Assessment
- Building Industrial IoT Gateways: Architecture and Best Practices
- How Do You Deploy Industrial IoT in a Brownfield Factory?
- How Do You Estimate the Cost of Unplanned Downtime?
Questions About Industrial IoT Pilot
Why pilot one line instead of the whole plant?
A single line pilot proves data quality, user adoption and measurable value with limited investment and disruption. Integration issues, unreliable signals and dashboard changes are found at small scale, where they are cheap to fix. The rollout recommendation then rests on evidence from your own machines rather than vendor assumptions.
Do we need a readiness assessment before the pilot?
It is recommended but not mandatory. If you already know the target line, machines, protocols, network constraints and success metrics, we can scope the pilot directly. If those are unclear, a Factory IoT Readiness Assessment first reduces the risk of choosing the wrong line or underestimating integration work.
How is OEE calculated from machine and PLC data?
Overall equipment effectiveness (OEE) multiplies availability, performance and quality. Availability uses machine run and stop states, performance compares actual cycle counts with ideal cycle time, and quality uses good versus rejected parts. A pilot collects these signals automatically from PLCs or sensors, then validates them against operator records.
Will the pilot interrupt production?
The pilot is designed to avoid modifying PLC control logic and to read data passively where possible. Some steps, such as installing sensors or connecting a gateway to a controller network, may need a short planned window, which is scheduled with your production team in advance.
Can the pilot hardware and software be reused for rollout?
Yes, that is the intent. The pilot uses the same architecture layers a plant wide deployment would use, so gateways, configuration patterns, dashboards and alert logic can be extended. The rollout recommendation states what can be reused and what must change at larger scale.
Ready to Scope Industrial IoT Pilot?
Share your product or plant context. An engineer reviews it and replies with questions, a proposed approach and next steps.
Discuss an Industrial IoT Pilot