Engineering Guides, Comparisons and Checklists
Practical material written by our engineers: answers first, tables for comparisons, numbered procedures and checklists you can use with your own team.
Engineering Checklists
Each checklist is a readable page and a printable PDF.
Factory IoT Readiness Checklist
This checklist helps plant heads, operations managers and Chief Technology Officers (CTOs) decide whether a factory is ready for an Industrial Internet of Things (IIoT) pilot. It covers business goals, machine and programmable logic controller (PLC) data access, network and operational technology (OT) security, data definitions and the people who will act on the data, so gaps are fixed before money is spent on hardware.
Embedded Product Development Checklist
This checklist helps product owners, engineering managers and Chief Technology Officers (CTOs) confirm that a new embedded product is ready to move from one development stage to the next. It covers requirements, architecture, hardware, firmware, validation and production readiness, so missing decisions surface during planning instead of during a costly board respin or field failure.
Firmware Security Audit Checklist
This checklist helps engineering managers, firmware leads and product security owners review the security of embedded firmware already shipping or close to release. It covers boot and update integrity, key management, debug access, communication, code quality and vulnerability handling, so the team can see which gaps carry the highest risk and fix those first.
BMS Integration Checklist: Battery and Building
This checklist covers two different systems that share the BMS abbreviation. Battery Management System (Battery BMS) sections help battery, electric vehicle (EV) and energy storage teams integrate a BMS with chargers, inverters and controllers. Building Management System (Building BMS) sections help facility and automation teams connect heating, ventilation and air conditioning (HVAC) units, meters and plant equipment to a central supervisory system.
PCB DFM Checklist
This checklist helps hardware engineers and engineering managers check a printed circuit board (PCB) for Design for Manufacture (DFM) and Design for Test (DFT) before releasing it for fabrication. It covers fabrication rules, components, assembly, testability and documentation, so issues that cause low yield, rework or a board respin are found while they are still cheap to fix.
Comparisons
Side by side tables for the protocol and platform decisions teams ask about most.
Modbus vs OPC UA vs MQTT: Which Protocol Fits a Factory Gateway?
Most factory Internet of Things (IoT) gateways use all three: Modbus reads meters, drives and older programmable logic controllers (PLCs), OPC UA (Open Platform Communications Unified Architecture) reads structured data from modern controllers, and MQTT (Message Queuing Telemetry Transport) publishes normalized data to a broker or cloud. This comparison explains where each fits and how to choose.
Read Modbus vs OPC UA vs MQTT: Which Protocol Fits a Factory Gateway?LoRaWAN vs NB IoT: Which LPWAN Fits Your Deployment?
Choose LoRaWAN (Long Range Wide Area Network) when you need your own network in unlicensed spectrum at sites with poor cellular coverage, and NB IoT (Narrowband Internet of Things) when operator coverage exists and you want devices to work without installing gateways. Both send small payloads at low power; they differ in cost model, latency and who owns the network.
Read LoRaWAN vs NB IoT: Which LPWAN Fits Your Deployment?BLE vs WiFi for IoT Devices: How Do You Choose?
Choose BLE (Bluetooth Low Energy) when the device runs on a battery, sends small amounts of data and can rely on a phone or gateway; choose WiFi when the device is mains powered, needs direct cloud access or higher throughput. Many products combine both, using BLE for setup and WiFi for data.
Read BLE vs WiFi for IoT Devices: How Do You Choose?Bare Metal vs RTOS Firmware: What Is the Difference?
Bare metal firmware runs your code directly on the microcontroller in a main loop with interrupts, while RTOS (real time operating system) based firmware runs tasks under a scheduler that handles priorities, timing and communication between tasks. Bare metal suits simple, tightly timed devices; an RTOS suits products with several concurrent activities such as connectivity, user interface and logging.
Read Bare Metal vs RTOS Firmware: What Is the Difference?Yocto vs Buildroot: Which Embedded Linux Build System to Use?
Use Buildroot when you need a small, fixed Linux image quickly and the team is small; use the Yocto Project when the product needs vendor BSP (board support package) layers, package management, SDKs (software development kits) for application teams, license compliance tooling and maintenance over many years. Both build a complete embedded Linux system from source.
Read Yocto vs Buildroot: Which Embedded Linux Build System to Use?SCADA vs MES vs Industrial IoT Platform: What Is the Difference?
SCADA (Supervisory Control and Data Acquisition) supervises and controls processes in real time, MES (Manufacturing Execution System) manages production orders, quality and traceability, and an Industrial IoT (Industrial Internet of Things) platform collects and contextualizes machine data for analytics across machines, lines and sites. They sit at different ISA 95 levels and usually complement each other.
Read SCADA vs MES vs Industrial IoT Platform: What Is the Difference?Battery BMS vs Building BMS: What Is the Difference?
A Battery Management System protects and monitors a battery pack by measuring cell voltages, current and temperature, while a Building Management System controls and monitors building services such as HVAC (heating, ventilation and air conditioning), lighting and energy meters. Both are called BMS, but they differ in purpose, hardware, protocols, standards and the engineering skills they require.
Read Battery BMS vs Building BMS: What Is the Difference?
Technical Guides
Step by step procedures for commissioning, integration and bring up work.
How Do You Connect an Existing PLC to an IoT Dashboard?
You connect an existing PLC (programmable logic controller) to an Internet of Things (IoT) dashboard by adding an industrial IoT gateway that reads the PLC through a protocol it already supports and publishes normalised tags over MQTT (Message Queuing Telemetry Transport) or HTTPS (Hypertext Transfer Protocol Secure). The PLC program stays unchanged and access stays read only.
Read How Do You Connect an Existing PLC to an IoT Dashboard?How Is OEE Calculated From Machine and PLC Data?
OEE (Overall Equipment Effectiveness) is calculated as Availability multiplied by Performance multiplied by Quality, using running state, total count and reject count from the PLC (programmable logic controller) plus planned production time and ideal cycle time from engineering data. This guide shows the formula, a worked example with hypothetical numbers and the data checks that keep the result honest.
Read How Is OEE Calculated From Machine and PLC Data?How Do You Deploy Industrial IoT in a Brownfield Factory?
You deploy Industrial IoT (Industrial Internet of Things) in a brownfield factory by surveying existing machines and networks, piloting on a few machines against one measured problem, retrofitting data acquisition without changing control logic, and scaling only after results beat the baseline. This guide covers phases, steps, a checklist and a method to estimate pilot return on investment (ROI).
Read How Do You Deploy Industrial IoT in a Brownfield Factory?How Do You Secure an Industrial IoT Gateway and OT Network Link?
You secure an industrial Internet of Things (IoT) gateway by segmenting it between operational technology (OT) and information technology (IT) networks, allowing only outbound encrypted connections with mutual Transport Layer Security (TLS), giving each device a unique identity, enforcing secure boot and signed updates, and keeping control devices read only. IEC 62443 gives that work a structure.
Read How Do You Secure an Industrial IoT Gateway and OT Network Link?How Are SOC and SOH Estimated in a Battery Management System?
State of charge (SOC) is estimated by counting charge in and out of the battery and correcting the drift with open circuit voltage readings or a model based filter; state of health (SOH) is estimated from measured capacity fade and internal resistance growth. A Battery Management System (Battery BMS) shares both over CAN (Controller Area Network) or Modbus.
Read How Are SOC and SOH Estimated in a Battery Management System?What Is BACnet and How Is It Integrated With Modbus in a Building BMS?
BACnet is the building automation protocol standardised by the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) as ASHRAE 135, and it models equipment as objects with properties. Modbus devices such as meters and chillers join a BACnet Building Management System (Building BMS) through a gateway that polls their registers and exposes them as BACnet objects.
Read What Is BACnet and How Is It Integrated With Modbus in a Building BMS?How Do You Perform Firmware Bring Up on a New Custom PCB?
You bring up firmware on a new custom printed circuit board (PCB) in verified stages: inspect and power the board with a current limit, confirm rails, reset and clocks, connect the debugger and run minimal code, then enable the console, clock tree, memory and each peripheral one at a time while logging results and board errata.
Read How Do You Perform Firmware Bring Up on a New Custom PCB?
Executive Briefings
How to estimate downtime cost, update risk and the gap between prototype and production.
How Do You Estimate the Cost of Unplanned Downtime?
You estimate the cost of unplanned downtime by adding lost contribution margin, idle labour, recovery, scrap and repair costs for each stoppage, then multiplying by how often it happens. This article gives plant heads a repeatable method per machine and per line, a hypothetical worked example and how machine visibility changes each input.
Read How Do You Estimate the Cost of Unplanned Downtime?What Is the Business Risk of a Failed OTA Update?
A failed Over the Air (OTA) update can brick devices in the field, and the cost then depends on how each device recovers: automatically, remotely, by a site visit or by replacement. This article shows executives how to estimate that exposure and which design controls, such as signing, A/B images, rollback and staged rollout, reduce it.
Read What Is the Business Risk of a Failed OTA Update?Why Does Unmaintainable Firmware Cost More Over Time?
Unmaintainable firmware costs more because every change, fix, security patch and component substitution takes longer and breaks more often than it should, for the whole life of the product. This article explains the warning signs, the metrics that make the cost visible, a method to estimate it and the remedies, from audit to targeted redesign.
Read Why Does Unmaintainable Firmware Cost More Over Time?Why Do Hardware Prototypes Fail to Reach Production?
Hardware prototypes fail to reach production because a working prototype proves function, not manufacturability, testability, compliance or supply. Closing the gap needs design for manufacture and test, staged Engineering, Design and Production Validation Test (EVT, DVT and PVT) builds, complete documentation and a resilient bill of materials (BOM). This article explains each step and the cost of skipping one.
Read Why Do Hardware Prototypes Fail to Reach Production?