Factory Energy Monitoring for Plant and Utilities Managers
EmbedCrest builds factory energy monitoring for plant heads, utilities managers and sustainability teams: power, voltage, current, power factor, kWh, demand and harmonics where meters measure them, allocated to machines and lines. The outcome is an energy baseline, cost reporting and energy per unit figures that show where consumption can be reduced or shifted.
Who this is for
- Plant Head
- Utilities and Energy Manager
- Sustainability Lead
- Factory Automation Head
- Finance Controller
Outcomes we work towards
- Energy use visible by machine, line and shift
- Reliable baseline for energy saving projects
- Early detection of idle consumption and abnormal loads
- Energy cost per unit available for costing decisions
One utility bill, no idea where the energy goes
Most plants see energy as a monthly utility bill or a few main meter readings. Without machine and line level data, nobody knows which equipment runs idle overnight, which compressor wastes power or how energy per unit changes with product mix. Savings projects are approved on estimates and cannot be verified afterwards. Existing meters are often installed but not connected, or their data stays in separate software nobody checks.
What We Design, Build and Hand Over
- Survey of existing energy meters, panels, feeders and measurement points
- Meter selection guidance and placement plan for gaps in coverage
- Meter integration over Modbus RTU or TCP, pulse outputs or other supported interfaces
- Capture of power, voltage, current, power factor, kWh, demand and harmonics where measured
- Allocation of energy to machines, lines, utilities and shifts
- Combination with production counts for energy per unit
- Baseline models and comparison against production and operating hours
- Cost reporting using your tariff structure, demand charges and time of use rates
- Alerts for abnormal consumption, idle loads and demand peaks
Energy monitoring data flow
Meter readings are collected by an edge gateway, aligned with production and machine state data, stored as time series and turned into allocation, baseline and cost reports.
Step 1
Meters and CTs
Main, feeder and machine level meters, current transformers and pulse outputs.
Step 2
Protocol layer
Modbus RTU or TCP and other supported meter interfaces polled on schedule.
Step 3
Edge gateway
Timestamping, scaling, buffering and alignment with machine state and counts.
Step 4
Time series storage
Interval energy, demand and electrical parameters with production context.
Step 5
Dashboards and reports
Allocation, baselines, energy per unit, cost and abnormal load alerts.
Step 6
ERP and reporting
Energy cost and sustainability data shared with finance tools where agreed.
Where Teams Use This
Compressed air and utility monitoring
Compressors, chillers, pumps and boilers are metered and compared with production demand, showing idle running, leaks reflected in load patterns and opportunities to adjust operating schedules.
Energy per unit by product
Energy consumption is combined with production counts per line and product, giving costing and sustainability teams a measured energy per unit instead of an allocated estimate.
Demand peak management
Interval demand is tracked against contracted limits, with alerts when a peak is building, so planners can stagger large loads and avoid avoidable demand charges.
Verifying an energy saving project
A baseline is recorded before a motor, drive or lighting upgrade, and the same method is used afterwards, so savings can be reported with a clear and repeatable calculation.
How the Work Runs
Metering survey
Review single line diagrams, existing meters and feeders, tariff structure and reporting needs, and identify measurement gaps.
Metering plan
Specify additional meters or current transformers and the allocation model linking feeders to machines, lines and utilities.
Integration build
Connect meters to the edge gateway, configure polling and scaling, and link production and machine state data.
Baseline period
Collect data over a representative period, check meter readings against utility bills and build the energy baseline.
Reporting and handover
Release dashboards, cost reports and alerts, train users and hand over the metering and allocation documentation.
What You Receive
- Metering survey and gap analysis
- Meter and current transformer specification
- Energy allocation model
- Configured gateway and meter integrations
- Energy dashboards with baseline and energy per unit
- Cost and demand reports
- Validation record against utility bills
How We Evidence the Work
No published case study maps directly to this page yet. These pages show the review, test and release evidence every engagement produces.
Have a similar challenge?
Share a short brief; an engineer replies within one business day. How engagements work
Prefer a fixed scope start? Factory IoT Readiness Assessment
Questions About Energy Monitoring
Which energy parameters can a factory energy monitoring system capture?
Typical parameters are active and reactive power, voltage, current, power factor, kWh, kVAh and maximum demand. Harmonics and other power quality values can be captured only where the installed meters measure them. Interval data is stored with timestamps, so consumption can be compared with production, shifts and machine states rather than viewed only as monthly totals.
Can you use the energy meters we already have?
Usually, yes. Many panel meters already provide Modbus RTU or TCP, or pulse outputs, and can be connected to an edge gateway. We check each meter model, its register map and accuracy class during the survey. Where coverage is missing, we specify additional meters or current transformers, which your licensed electricians install.
How is energy allocated to individual machines and lines?
Where a machine has its own meter, allocation is direct. Where several loads share a feeder, we combine feeder data with machine states, rated loads or sub metering to estimate each share, and label those values as estimated. The allocation model is documented, so finance and engineering teams understand which figures are measured and which are calculated.
How do you build an energy baseline?
A baseline relates energy use to the factors that drive it, such as production volume, operating hours and sometimes ambient temperature, over a representative period. Future consumption is compared with what the baseline predicts for the same conditions. This separates real savings from changes caused by lower output or weather, and gives a consistent method for evaluating projects.
Is energy monitoring the same as a Building Management System?
No. A Building Management System (Building BMS) controls and monitors building services such as HVAC, lighting and access. Factory energy monitoring measures electrical consumption of production equipment and utilities and links it to output. The two can share meters and data, and we can integrate energy data with an existing Building BMS where that is in scope.
Ready to Scope Energy Monitoring?
Share your product or plant context. An engineer reviews it and replies with questions, a proposed approach and next steps.
Request an Energy Monitoring Survey