Building Management System (Building BMS) Integration and Gateways

EmbedCrest develops Building Management System (Building BMS) gateways, controllers and integration software for facility owners, building technology OEMs and system integrators, so HVAC plant, lighting, meters and alarms report into one consistent data model. We handle BACnet, Modbus, KNX, DALI and MQTT integration, point mapping, trend logging and energy visibility for new and existing buildings.

Technically reviewed by the EmbedCrest engineering teamUpdated

Who this is for

  • Building technology and HVAC equipment OEMs
  • Building automation system integrators
  • Facility and energy managers
  • Smart building platform product teams

Outcomes we work towards

  • One consistent view of HVAC, lighting and metering data
  • Faster detection of equipment faults and comfort issues
  • Better visibility of where building energy is used
  • Reuse of existing controllers instead of replacement

Why building systems stay disconnected

Most buildings run equipment from several vendors installed over many years. Chillers speak Modbus, newer controllers speak BACnet, lighting uses DALI or KNX and meters sit on their own network. Point names are inconsistent, documentation is missing and alarms go nowhere useful. Facility teams end up walking plant rooms to check status, energy waste goes unnoticed and replacing every controller to get one platform is rarely affordable. Integration needs careful protocol work, not just another dashboard.

Scope

What We Design, Build and Hand Over

  • Survey of HVAC plant, lighting, access, occupancy, meters and alarms with a protocol inventory
  • Integration of chillers, AHUs, FCUs, pumps, cooling towers, boilers and ventilation equipment
  • BACnet/IP, BACnet MS/TP, Modbus TCP and RTU, KNX, DALI and MQTT integration where supported
  • Building gateway firmware: protocol conversion, point mapping, scheduling and local control
  • Trend logging, alarm routing and cloud integration through MQTT or documented vendor APIs
  • HVAC energy monitoring, equipment runtime, comfort conditions and fault detection rules
  • Occupancy based control logic and energy dashboards for facility teams
  • Retrofit support: legacy controller integration, point schedules and sequence of operation review
  • Commissioning support: alarm testing, trend validation and documented handover
Architecture

Building BMS integration architecture

Field equipment and controllers connect to a building gateway that normalises points from several protocols, applies schedules and local logic, and publishes trends and alarms to a supervisory BMS or cloud platform.

  1. Step 1

    Field equipment

    Chillers, AHUs, FCUs, pumps, boilers, lighting, meters and occupancy sensors

  2. Step 2

    Field controllers

    BACnet MS/TP, Modbus RTU, KNX and DALI controllers on existing building networks

  3. Step 3

    Building gateway

    Protocol conversion, point mapping, schedules, local control and trend buffering

  4. Step 4

    Supervisory BMS

    BACnet/IP supervisory system or head end for operators and alarm handling

  5. Step 5

    Cloud and analytics

    MQTT or API integration feeding energy dashboards and fault detection rules

Building BMS integration architecture
Comparison

Battery BMS vs Building BMS: what each system does

Battery BMS vs Building BMS: what each system does
AspectBattery BMSBuilding BMS
Full nameBattery Management SystemBuilding Management System
Main purposeProtect and monitor a battery packControl and monitor building services
Typical inputsCell voltages, pack current, temperaturesHVAC points, meters, occupancy, alarms
Common protocolsCAN, CAN FD, RS485, ModbusBACnet, Modbus, KNX, DALI, MQTT
Response timeMilliseconds for protectionSeconds to minutes for control
Where it runsInside the pack or battery systemAcross a building or campus
Use Cases

Where Teams Use This

Connecting legacy chillers to a BACnet supervisory system

A Modbus to BACnet gateway exposes chiller status, setpoints and alarms to an existing supervisory system, with a documented point list, so operators manage old and new plant from one interface without replacing controllers.

Multi site energy visibility for commercial buildings

Gateways at each site collect meter and HVAC data and publish it over MQTT to a central platform, giving energy managers comparable consumption, runtime and comfort data across a portfolio of buildings.

Smart building product gateway for an OEM

Embedded gateway firmware for a building technology OEM that needs its product to speak BACnet and Modbus to third party systems while sending data to its own cloud service.

Occupancy based HVAC and lighting control

Integration of occupancy sensors with HVAC and DALI or KNX lighting so that unoccupied zones move to setback schedules, with trend logs that let facility teams verify comfort and energy behaviour.

Process

How the Work Runs

  1. Site and system discovery

    We collect drawings, controller lists, protocol details and existing point names, and identify which systems can be integrated and how.

  2. Point schedule and architecture

    We produce a point schedule, naming convention, gateway architecture and integration plan agreed with your facility team and contractor.

  3. Gateway and software build

    We configure or develop gateway firmware, mappings, schedules, alarm rules and cloud integration, and test them against simulated devices.

  4. Integration and commissioning support

    Working with your contractor, we connect live systems, test alarms, validate trends and review sequences of operation.

  5. Handover and optimisation

    We hand over documentation and configuration backups, train the facility team and tune fault detection and energy reports after go live.

Deliverables

What You Receive

  • Protocol inventory and integration feasibility report
  • Point schedule with agreed naming convention
  • Gateway architecture and network diagram
  • Gateway firmware or configuration with version history
  • Alarm and trend validation records
  • Energy dashboard and fault detection rule definitions
  • Handover documentation and operator guide
Proof

How We Evidence the Work

No published case study maps directly to this page yet. These pages show the review, test and release evidence every engagement produces.

Have a similar challenge?

Share a short brief; an engineer replies within one business day. How engagements work

Prefer a fixed scope start? BMS Integration Assessment

Discuss Your Building BMS Integration
FAQ

Questions About Building BMS Integration

What is BACnet and how is it integrated with Modbus in a building BMS?

BACnet (Building Automation and Control Networks) is an open protocol standard for building automation, and Modbus is a simpler register based protocol common on chillers, meters and drives. In a Building BMS, a gateway reads Modbus registers, scales and names each value, and exposes them as BACnet objects such as analog inputs and binary values. The supervisory system then treats Modbus equipment like native BACnet devices, using a documented point mapping.

How can an existing HVAC system be connected to a centralized BMS?

An existing HVAC system is usually connected through its controllers, not by replacing them. We first check which protocols the controllers support, such as BACnet MS/TP, Modbus RTU or a vendor interface. A gateway then reads the required points, maps them to a common naming scheme and publishes them to the central Building BMS over BACnet/IP or MQTT. Where a controller has no usable interface, additional sensors or an interface module may be needed.

Does EmbedCrest install building automation systems?

No. EmbedCrest develops controllers, gateways and integration software, and supports commissioning remotely or alongside your team. Licensed electrical and HVAC installation, wiring, panel work and site safety are delivered by your installation contractor. This split lets you keep your preferred local contractor while we handle protocol integration, point mapping, gateway firmware and data quality.

Which building protocols can you integrate?

We integrate BACnet/IP, BACnet MS/TP, Modbus TCP and Modbus RTU, and can work with KNX, DALI and MQTT, plus documented vendor APIs where supported. The protocols for each project are confirmed during discovery and listed in the statement of work. If a system uses a closed proprietary protocol without documentation or a vendor gateway, we will tell you early rather than promise an integration we cannot verify.

Can a Building BMS help reduce energy consumption?

A Building BMS can help reduce energy use by making waste visible and enabling better control. Trend data shows equipment running outside occupied hours, simultaneous heating and cooling or drifting setpoints. Occupancy based schedules and fault detection rules then act on that data. Actual savings depend on the building, its equipment and how the facility team uses the information, so we measure against an agreed baseline.

Ready to Scope Building BMS Integration?

Share your product or plant context. An engineer reviews it and replies with questions, a proposed approach and next steps.

Discuss Your Building BMS Integration
Discuss Your Building BMS Integration