SCADA vs MES vs Industrial IoT Platform: What Is the Difference?
Industrial

SCADA vs MES vs Industrial IoT Platform: What Is the Difference?

SCADA (Supervisory Control and Data Acquisition) supervises and controls processes in real time, MES (Manufacturing Execution System) manages production orders, quality and traceability, and an Industrial IoT (Industrial Internet of Things) platform collects and contextualizes machine data for analytics across machines, lines and sites. They sit at different ISA 95 levels and usually complement each other.

November 16, 20266 min read
Battery BMS vs Building BMS: What Is the Difference?
Industrial

Battery BMS vs Building BMS: What Is the Difference?

A Battery Management System protects and monitors a battery pack by measuring cell voltages, current and temperature, while a Building Management System controls and monitors building services such as HVAC (heating, ventilation and air conditioning), lighting and energy meters. Both are called BMS, but they differ in purpose, hardware, protocols, standards and the engineering skills they require.

November 16, 20266 min read
How Do You Connect an Existing PLC to an IoT Dashboard?
Industrial

How Do You Connect an Existing PLC to an IoT Dashboard?

You connect an existing PLC (programmable logic controller) to an Internet of Things (IoT) dashboard by adding an industrial IoT gateway that reads the PLC through a protocol it already supports and publishes normalised tags over MQTT (Message Queuing Telemetry Transport) or HTTPS (Hypertext Transfer Protocol Secure). The PLC program stays unchanged and access stays read only.

November 16, 20267 min read
How Is OEE Calculated From Machine and PLC Data?
Industrial

How Is OEE Calculated From Machine and PLC Data?

OEE (Overall Equipment Effectiveness) is calculated as Availability multiplied by Performance multiplied by Quality, using running state, total count and reject count from the PLC (programmable logic controller) plus planned production time and ideal cycle time from engineering data. This guide shows the formula, a worked example with hypothetical numbers and the data checks that keep the result honest.

November 16, 20267 min read
How Do You Deploy Industrial IoT in a Brownfield Factory?
Industrial

How Do You Deploy Industrial IoT in a Brownfield Factory?

You deploy Industrial IoT (Industrial Internet of Things) in a brownfield factory by surveying existing machines and networks, piloting on a few machines against one measured problem, retrofitting data acquisition without changing control logic, and scaling only after results beat the baseline. This guide covers phases, steps, a checklist and a method to estimate pilot return on investment (ROI).

November 16, 20267 min read
How Do You Secure an Industrial IoT Gateway and OT Network Link?
Security

How Do You Secure an Industrial IoT Gateway and OT Network Link?

You secure an industrial Internet of Things (IoT) gateway by segmenting it between operational technology (OT) and information technology (IT) networks, allowing only outbound encrypted connections with mutual Transport Layer Security (TLS), giving each device a unique identity, enforcing secure boot and signed updates, and keeping control devices read only. IEC 62443 gives that work a structure.

November 16, 20267 min read
How Are SOC and SOH Estimated in a Battery Management System?
Firmware

How Are SOC and SOH Estimated in a Battery Management System?

State of charge (SOC) is estimated by counting charge in and out of the battery and correcting the drift with open circuit voltage readings or a model based filter; state of health (SOH) is estimated from measured capacity fade and internal resistance growth. A Battery Management System (Battery BMS) shares both over CAN (Controller Area Network) or Modbus.

November 16, 20267 min read
What Is BACnet and How Is It Integrated With Modbus in a Building BMS?
IoT

What Is BACnet and How Is It Integrated With Modbus in a Building BMS?

BACnet is the building automation protocol standardised by the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) as ASHRAE 135, and it models equipment as objects with properties. Modbus devices such as meters and chillers join a BACnet Building Management System (Building BMS) through a gateway that polls their registers and exposes them as BACnet objects.

November 16, 20267 min read
How Do You Perform Firmware Bring Up on a New Custom PCB?
Firmware

How Do You Perform Firmware Bring Up on a New Custom PCB?

You bring up firmware on a new custom printed circuit board (PCB) in verified stages: inspect and power the board with a current limit, confirm rails, reset and clocks, connect the debugger and run minimal code, then enable the console, clock tree, memory and each peripheral one at a time while logging results and board errata.

November 16, 20267 min read