Embedded Telemetry and Grid Edge Engineering for Energy and Utilities
For utilities, energy equipment makers and renewable operators, EmbedCrest develops smart meter firmware, remote terminal units, grid edge gateways and asset telemetry for transformers, solar plants and battery storage. The outcome is distributed assets that report reliably from remote sites, can be managed and updated as a fleet, and feed operations systems with trustworthy data.
Who this is for
- Utility Engineering and Operations Head
- Energy Equipment OEM Product Manager
- Renewable Asset Manager
- Metering Solution Integrator
Outcomes we work towards
- Fewer site visits for remote assets
- More reliable data from field devices
- Safer, managed firmware updates at fleet scale
- Earlier warning of asset faults
Thousands of remote devices, intermittent links and long lifetimes
Energy assets are spread across substations, rooftops, feeders and remote plants, often with weak cellular coverage and lifetimes of ten years or more. Devices must keep accurate records through outages, survive harsh enclosures and accept updates without truck rolls. Utilities also face mixed protocols across vendors and growing security expectations. Off the shelf devices rarely fit every site, and custom firmware without fleet management becomes a liability as deployments grow.
What We Design, Build and Hand Over
- Smart meter and submeter firmware with metrology integration and tamper detection
- Remote terminal unit and data logger firmware for substations and distributed assets
- Grid edge gateways supporting Modbus, DLMS/COSEM or IEC 104 telecontrol where agreed
- Transformer and feeder telemetry for temperature, load and oil or gas sensors
- Solar inverter, string and BESS monitoring integration
- NB IoT, LTE M, LoRaWAN or RF mesh connectivity with store and forward
- Device management, secure boot and signed OTA updates for large fleets
Grid edge telemetry architecture
Field devices measure and protect locally, gateways aggregate and buffer data across unreliable links, and head end systems feed operations, billing and analytics while device management keeps the fleet secure and current.
Step 1
Field assets
Meters, transformers, inverters, battery racks and protection relays.
Step 2
Measurement devices
Metrology, sensor interfaces, event logs and tamper detection firmware.
Step 3
Grid edge gateway
Protocol conversion, local logic and store and forward buffering.
Step 4
Communication network
NB IoT, LTE M, LoRaWAN, RF mesh or fibre backhaul.
Step 5
Head end and management
Data collection, device management and secure update campaigns.
Step 6
Operations systems
SCADA, billing, outage and asset analytics owned by the utility.
Where Teams Use This
Distribution transformer monitoring
A retrofit unit measures load, oil temperature and enclosure conditions on distribution transformers and reports over NB IoT, helping operators spot overloads and plan replacements before failures.
Solar plant string and inverter telemetry
Gateways collect inverter and string data over Modbus, buffer it during outages and forward it to the asset management platform, highlighting underperforming strings for cleaning or repair.
Smart submeter for commercial sites
Submeter firmware with metrology integration, tamper events and wireless reporting gives landlords and energy managers interval data per tenant or feeder, replacing monthly manual reading and estimated bills.
Firmware update programme for an installed meter fleet
Signed images, staged rollout and rollback design allow a utility or OEM to update field devices safely in batches, with reporting on success per device.
How the Work Runs
Asset and site analysis
Review asset types, site conditions, connectivity coverage, existing systems and data the operations team needs.
Device and network design
Select measurement hardware, communication technology, protocols and the device management approach that suits the size of the fleet.
Firmware and gateway build
Develop metrology integration, logging, protocols and secure update mechanisms, with careful power loss and outage handling.
Pilot deployment
Deploy a pilot batch with your field team, monitor data quality, link behaviour and update success.
Fleet scaling
Finalize production configuration, provisioning, installation guides and update procedures for a controlled rollout across all sites.
What You Receive
- Device and gateway architecture specification
- Firmware source with secure boot and OTA design
- Protocol implementation and integration test reports
- Connectivity and power budget analysis
- Pilot data quality and link performance report
- Provisioning and fleet update procedures
How We Evidence the Work
No published case study maps directly to this page yet. These pages show the review, test and release evidence every engagement produces.
Have a similar challenge?
Share a short brief; an engineer replies within one business day. How engagements work
Prefer a fixed scope start? BMS Integration Assessment
Questions About Energy and Utilities
Which communication technology suits remote energy assets?
It depends on data volume, power and coverage. NB IoT (Narrowband IoT) and LTE M suit low data meters and sensors with cellular coverage, LoRaWAN suits private networks over wide rural areas, and fibre or 4G suits substations and plants with higher data needs. We usually compare options with a coverage check at representative sites.
How do you keep data safe when a site loses connectivity?
Devices use store and forward buffering: readings and events are written to non volatile memory with timestamps and sent when the link returns, oldest first or by priority. Buffer size, retention and clock synchronization are sized for the longest outage you expect so records stay complete and ordered.
Can firmware be updated safely on thousands of field devices?
Yes, with the right design. Images are signed and verified by a secure bootloader, devices keep a fallback image for rollback, and updates are released in staged batches with health checks between them. Device management reports success or failure per unit so problems are caught before the whole fleet is affected.
Do you handle meter certification?
No. Meter type approval and revenue accuracy certification are performed by accredited labs for the meter manufacturer or utility. We develop firmware and electronics with those requirements in mind, support pre compliance testing and prepare the engineering documentation the lab needs.
Which utility protocols do you support?
Modbus RTU and TCP and MQTT are routine for us. Utility specific protocols such as DLMS/COSEM for metering or the IEC 104 telecontrol protocol are scoped per project, using proven protocol libraries where possible, and we confirm support in the statement of work rather than assume it.
Ready to Scope Energy and Utilities?
Share your product or plant context. An engineer reviews it and replies with questions, a proposed approach and next steps.
Discuss Your Grid Edge Project