Battery BMS Firmware and BESS Monitoring Engineering
For battery pack manufacturers, energy storage integrators and EV battery teams, EmbedCrest develops Battery Management System (Battery BMS) firmware, cell monitoring, state estimation, CAN integration and telemetry for packs and Battery Energy Storage Systems (BESS). The outcome is packs that report trustworthy state, protect cells and integrate cleanly with chargers, inverters and monitoring platforms.
Who this is for
- EV and Battery Engineering Lead
- Battery Pack Product Manager
- BESS Integrator Engineering Head
- Energy Storage Startup CTO
Outcomes we work towards
- More reliable state of charge and health reporting
- Faster integration with chargers and inverters
- Earlier detection of cell and thermal anomalies
- Fleet wide visibility of pack condition
Battery data is only as good as the BMS behind it
Battery packs and storage systems depend on the Battery BMS to measure cells, balance them, estimate charge and health, and stop unsafe operation. Inaccurate estimation erodes usable capacity and warranty decisions, while weak communication with chargers or inverters causes nuisance trips and commissioning delays. At BESS scale, operators also need rack and container level telemetry, but many systems expose only vendor screens with no clean data path to monitoring and maintenance tools.
What We Design, Build and Hand Over
- Battery BMS firmware for cell voltage, current and temperature measurement and protection
- Analog front end integration for cell monitoring and passive or active balancing
- State of charge and state of health estimation with calibration and validation
- CAN or CAN FD communication with chargers, inverters, vehicle and power conversion controllers
- Pack telemetry over cellular, LoRaWAN or Ethernet with fault and event logging
- BESS rack and container monitoring through Modbus or CAN gateways to SCADA or cloud
- HIL test setups with cell simulators for protection and estimation regression
- Bootloaders and secure firmware updates for packs in the field
Battery data from cell to fleet dashboard
Cell measurements flow through the Battery BMS, which protects the pack and estimates its state, then to power conversion controllers and a telemetry gateway that feeds monitoring and analytics for single packs or BESS sites.
Step 1
Cells and sensors
Cell voltages, pack current shunt or Hall sensor, temperature sensors and contactors.
Step 2
Analog front end
Cell monitoring ICs handling measurement, balancing and isolated communication.
Step 3
Battery BMS controller
Protection logic, SOC and SOH estimation, fault memory and contactor control.
Step 4
Power interface
CAN or CAN FD messaging with charger, inverter or vehicle controller.
Step 5
Telemetry gateway
Rack or pack data aggregation, buffering and secure upload over cellular or Ethernet.
Step 6
Monitoring platform
Health trends, alarms, warranty data and BESS site dashboards.
Battery BMS compared with Building BMS
| Aspect | Battery Management System | Building Management System |
|---|---|---|
| Purpose | Protects and manages battery cells | Controls and monitors building services |
| Typical data | Cell voltage, current, temperature, SOC, SOH | HVAC states, energy, occupancy, air quality |
| Common protocols | CAN, CAN FD, SMBus, Modbus | BACnet, Modbus, KNX, MQTT |
| Where it runs | Inside the pack or rack | Across a building or campus |
Where Teams Use This
BMS firmware for a light electric vehicle pack
Protection, balancing and state of charge estimation on a microcontroller based Battery BMS, with CAN messaging to the vehicle controller and charger and fault logs that service teams can read.
BESS rack telemetry and alarms
A gateway that collects rack and string data from each Battery BMS over Modbus or CAN, normalizes it and sends it to SCADA or a cloud dashboard with alarm handling for operations staff.
Second life battery assessment
Firmware and test tooling to measure capacity, internal resistance and imbalance of used modules, so a refurbisher can grade them before reuse in stationary storage.
Connected packs for rental or swapping fleets
Cellular telemetry that reports state of charge, health, location and abuse events for every pack in a swapping or rental network, supporting dispatch, maintenance and warranty decisions.
How the Work Runs
Pack and system review
Review cell chemistry, pack topology, protection requirements, interfaces and any existing Battery BMS firmware or hardware.
BMS architecture
Define measurement chain, protection thresholds, estimation approach, communication matrix and telemetry needs with your battery engineers.
Firmware and integration
Implement protection, estimation and communication firmware, then integrate it with your chargers, inverters or vehicle controllers on the bench.
Validation on HIL
Use cell simulators and fault injection to verify protection limits, estimation behaviour and communication before testing real packs.
Field rollout support
Support pilot packs or sites, analyse telemetry, tune estimation and hand over update and monitoring procedures.
What You Receive
- Battery BMS software architecture and protection specification
- Firmware source with build and flashing tools
- SOC and SOH estimation description and validation results
- CAN or Modbus communication matrix and integration report
- HIL test cases and protection verification report
- Telemetry data model and dashboard or SCADA integration
How We Evidence the Work
No published case study maps directly to this page yet. These pages show the review, test and release evidence every engagement produces.
Have a similar challenge?
Share a short brief; an engineer replies within one business day. How engagements work
Prefer a fixed scope start? BMS Integration Assessment
Questions About Battery and Energy Storage
What is the difference between a Battery Management System and a Building Management System?
Both are called BMS but solve different problems. A Battery Management System monitors and protects battery cells, estimating charge and health and controlling contactors. A Building Management System controls and monitors building services such as HVAC, lighting and energy. EmbedCrest engineers both, as separate services with different protocols and teams of stakeholders.
How are SOC and SOH estimated in a battery management system?
State of charge (SOC) is usually estimated by counting current over time and correcting drift with voltage based models or a Kalman filter. State of health (SOH) compares present capacity and internal resistance with the cell at beginning of life. Both need calibration with your cell data and validation across temperature and ageing conditions.
How does a BMS communicate with an inverter, charger or vehicle controller?
Most commonly over CAN or CAN FD using a message set agreed between suppliers, sometimes over Modbus RTU or TCP for stationary storage. The Battery BMS reports limits such as maximum charge and discharge current, plus state and faults, and the charger or inverter must respect them. We implement and test that matrix on both sides of the interface.
Can you add telemetry to an existing battery pack design?
Often yes. If the existing Battery BMS exposes data over CAN, Modbus or a serial port, a telemetry module can read it without changing protection firmware. Where the BMS exposes too little, we assess a firmware update or a redesigned controller. Our BMS integration assessment reviews the options before any hardware change.
Do you certify battery packs for safety standards?
No. Pack safety certification, such as transport testing or stationary storage standards, is carried out by accredited labs on behalf of the pack maker. We design firmware and electronics with those requirements in mind, support pre compliance testing and supply documentation your certification body asks for from the engineering side.
Ready to Scope Battery and Energy Storage?
Share your product or plant context. An engineer reviews it and replies with questions, a proposed approach and next steps.
Book a BMS Integration Assessment